Laurence Power, of Robert Gordon University in Aberdeen, Scotland, an engineering teacher who has studied these valves in offshore oil wells, said he has "not been able to see their logic" for reducing the frequency of testing. In 1999, right after that rule change, an MMS-commissioned report by a research group identified 117 blowout preventer failures at deepwater rigs within the previous year. These breakdowns created 3,638 hours of lost time
-- a 4 percent chunk of drilling time. In 2004, an engineering study for federal regulators said only 3 of 14 new devices could shear pipe, as sometimes required to check leaks, at maximum rated depths. Only half of operators accepting a newly built device tested this function during commissioning or acceptance, according to the report. "This grim snapshot illustrates the lack of preparedness in the industry to shear and seal a well with the last line of defense against a blowout," the report warned. Two years later, a trade journal's article still noted that shearing preventers "may also have difficulty cutting today's high-strength, high toughness drill pipe" at deep wells. The special cutting preventers were blamed in 1979 for the biggest peacetime well spill in history, when about 140 million gallons of oil poured from a Mexican well in the Gulf.
Questions about reliability hung heavily but were mostly unspoken Thursday at a Houston conference on offshore oil rig technology. Shown a spreadsheet of problems with blowout preventers, Transocean technology manager John Kozicz said, "We know that
-- but they don't happen frequently." Even Transocean's Earl Shanks, lead author of the 2003 study reporting "poor BOP reliability," now views blowout preventers as "very reliable." But he did acknowledge problems in the complex electronic and hydraulic tangle that activates and controls the devices. At Deepwater Horizon, he said, "Something went wrong
-- and we don't know what." Cameron International, which made the Deepwater Horizon preventers, has acknowledged that these lumbering emergency stoppers need lots of upkeep. "You have to maintain it," CEO Jack Moore told investors last year. "You have to replace the mechanical and rubber elements." Cameron International did not respond to AP questions about reliability. But it has had to face such questions in court. A 2008 federal lawsuit claims its faulty blowout preventers contributed to a well blowout. The suit makes the same claim about other valves installed at the rig but made by Hydril. A Hydril Pressure Control representative said he couldn't be quoted by name under company policy, but he defended the safety of his company's preventers. Asked about the lawsuit, he said, "It is a matter of litigation, and we have denied the allegation and strongly believe in the merits of our case."
[Associated
Press;
Copyright 2010 The Associated Press. All rights reserved. This material may not be published, broadcast, rewritten or redistributed.